TROUBLESHOOTING & REPAIR

F-76

F-76

COMMANDER 300

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

POWER SUPPLY TEST

(continued)

TEST PROCEDURE

1. Turn the engine off.

2. Perform the Case Cover Removal and

Replacement Procedure and tilt the control
panel out.

ELECTRIC SHOCK CAN KILL.

• Do not touch electrically live

parts such as output termi-
nals or internal wiring.

• Insulate yourself from the

work and ground.

• Always wear dry insulating

gloves.

3. Start the machine.

4. Using a voltmeter, measure the following sup-

ply voltages at the designated points. See
Table F.4.

5. Turn the engine off.

6. Using the Case Cover Removal and

Replacement Procedure, install the control
panel and side panels on the machine.

Table F.4

+12VDC control

+12VDC control

+12VDC control

30VAC control

30VAC control

42VAC control

+12VDC control

+12VDC Battery

J2 pin 3 to 2 @ control bd

J1 pin 4 to 1 @ control bd

J5 pin 4 to 1 @ engine prot. bd

J12 pin 1 to 2 @ LT chopper bd

J13 pin 1 to 2 @ RT chopper bd

J3 pin 1 to 9 @ control bd

J9 pin 4 to 5 @ display bd

J9 pin 1 to 2 @ display bd

(run/stop on)

Weld output/display output

Idler control

Idler control

Weld output

Weld output

Weld output

Display output (if so equipped)

Display output (if so equipped)

Control board

Control board

leads 108, 109/cont. bd

leads 15, 16

leads 13, 14

leads 17, 18

leads 106, 107/cont. bd

leads 232, 232J, 5L, 5N,

5M/Battery

SUPPLY VOLTAGE

MEASURED AT:

FUNCTION AFFECTED

CHECK/REPLACE

Note: When checking leads for continuity or poor connection, remember to look closely for

broken molex pins.