TROUBLESHOOTING & REPAIR

F-7

F-7

COMMANDER 300

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely,
contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

FUNCTION PROBLEMS

The output control on the
Commander 300 does not work
properly.

1. Make sure the Remote/Local

switch is in the “Local” position.

2. The output control (R1) may be

defective.

1. Check the Remote/Local switch

and associated wiring. See the
Wiring Diagram. (leads #75,
#76 and #77)

2. Perform the Power Supply

Test.

3. Perform the Control Input

Test.

4. Perform the Feedback Input

Test.

5. Perform the PWM Output Test.

6. Perform the Power Module

Test.

The remote output control does not
function properly.

1. Make sure the Remote/Local

switch is in the “Remote” posi-
tion.

2. The remote control unit may be

faulty. Repair or replace.

1. Check the Remote/Local switch

and associated leads. See the
Wiring Diagram.

2.

Check the amphenols and
associated leads. See the
Wiring Diagram.

3. Perform the RF Bypass Board

Resistance Test.