FEEDBACK INPUT TEST

(continued)

FIGURE F.32 - CONTROL BOARD

G3002-1

COMMANDER 300

CONTROL

Q1

C1

C54

C2

C25

X4

X8

X2

X10

X12

X13

X18

X11

X5

X19

X1

J1

J2

J3

J4

TEST PROCEDURE

1. Turn the engine off.

2. Using the Case Cover Removal and

Replacement Procedure and tilt the control
panel out.

ELECTRIC SHOCK CAN KILL.

• Do not touch electrically

live parts such as output
terminals or internal wiring.

• Insulate yourself from the

work and ground.

• Always wear dry insulating

gloves.

3. Start the machine.

4. In CC mode and with the weld terminal switch

in the “always on” position, load the machine
on a load grid to 200 amps at 25 VDC using
an external ammeter and voltmeter to mea-
sure weld amps and volts.

5. With a voltmeter, measure the voltage from J3

pin 15 (pos. lead) to J3 pin 6 (neg. lead). See
Figure F.33.
The voltage should be approxi-
mately 25 mvdc.

6. If the voltage is off by more than 2.5 mvdc, the

shunt and lead assembly is bad. Replace.

7. Locate the J2 connector on the control PC

board. Keep the machine running and same
grid load applied.

8. Using a voltmeter, measure the voltage from

J2 pin 1 (pos. lead) to J2 pin 2 (neg. lead).
See Figure F.33. The voltage should read
1.788 - 2.185 VDC.

9. In the CC mode, load the machine to 200

amps at 30 VDC using an external ammeter
and voltmeter.

10. Using a voltmeter, measure the voltage from

J2 pin 5 (pos. lead) to J2 pin 2 (neg.lead).
See Figure F.33. The voltage should read
3.521 - 3.739 VDC.

11. Remove the load and turn the engine off.

12. If any of the voltage checks fail, proceed to

the continuity check section.

CONTINUITY CHECKS SECTION:

1. Locate and disconnect J3 at the control PC

board.

2. Using an ohmmeter, check for continuity from

J3 pin 15 to J3 pin 6. See Figure F.33. Also
check for continuity from J3 pin 6 to the nega-
tive stud.

3. If either continuity test does not measure 0

ohms, check for continuity and poor connec-
tions on leads 21 and 22 from the shunt back
to the control board. See the wiring diagram.
Look closely for broken molex pins.

4. If all leads check ok, the shunt is bad.

Replace.

5. Using an ohmmeter, check for continuity from

J3 pin 2 to the positive stud.