THEORY OF OPERATION

E-4

E-4

COMMANDER 300

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

CONTROL TRANSFORMER AND
CONTROL BOARD

The control transformer primary winding is powered by
the 115VAC auxiliary coil in the stator. Three sec-
ondary voltages are developed by the control trans-
former. The 42VAC is applied to the control board
where it is rectified and used to operate the control
board circuitry. The two isolated 30VAC windings sup-
ply power to the IGBT driver circuits.

The control board monitors the operator controls (out-
put, mode selector and arc control). It compares these
commands to the current and voltage feedback infor-
mation it receives from the shunt and output terminals.
The circuitry on the control board determines how the
output should be controlled to optimize welding results
and sends the correct PWM signals to the IGBT driver
circuits.

NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.

FIGURE E.4 – CONTROL TRANSFORMER AND CONTROL BOARD

ENGINE

CONTROL

BOARD

ROTOR

CONTROL

TRANSFORMER

STATOR

AUXILIARY

WINDINGS

ENGINE

PROTECTION

BATTERY

W

E

L

D

W

I

N

D

I

N

G

CHOKE

IGBT

IGBT

SHUNT

TO

CONTROL

BOARD

MECHANICAL

ROTATION

STARTER

ALTERNATOR

ENGINE

SENSORS

SOL

SOL

S
H
U
T
D
O

W

N

I

D
L
E
R

ARC

CONTROL

OUTPUT

CONTROL

MODE

SELECTOR

POWER MODULES

THREE-PHASE

RECTIFIER

WORK

TERMINAL

ELECTRODE

TERMINAL

__

+

42VAC

30VAC

30VAC

1
1
5
V

A
C

115VAC

RECEPTACLE

230VAC

RECEPTACLE

SLIP

RINGS

(TWO)

TO

CONTROL

BOARD