Troubleshooting & repair, Normal open circuit voltage waveform (stick) – Lincoln Electric COMMANDER SVM145-B User Manual
Page 136
Advertising
TROUBLESHOOTING & REPAIR
F-80
F-80
COMMANDER 300
This is the typical DC open circuit out-
put voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 5 milliseconds in time.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (STICK)
MAX TAP – MAX CONTROL POT – HIGH IDLE – NO LOAD
0 volts
50V
5ms