FIGURE F.41 – POWER MODULE/OUTPUT RECTIFIER BRIDGE ASSEMBLY DETAILS

13. Free the positive output lead. Cut any nec-

essary cable ties and slip the lead through
the current sensing toroid assembly.

14. The power module/output rectifier bridge

assembly can now be removed and set to
the side.

NOTE: Leads #68A and #69A will remain
attached between the machine and the assembly.
To completely remove the assembly, label and
disconnect leads #68A and #69A at their bolted
connections beneath the bottom bracket.

DIODE &
"W" LEAD
TERMINAL (3)

GLASTIC
INSULATOR
BRACKET

POWER MODULE
HEAT SINK

POWER
MODULE
PC BOARD
(CHOPPER
PC BOARD)

CAPACITOR

BASE BOLT (4)

CONTROL
TRANSFORMER

DIODE
HEATSINK

DIODE
LEADS

BOTTOM
BRACKET

TOP
BRACKET