TROUBLESHOOTING & REPAIR

F-81

F-81

COMMANDER 300

This is the typical DC output voltage
generated from a properly operating
machine. Note that each vertical
division represents 20 volts and that
each horizontal division represents 5
milliseconds in time.

The machine was loaded with a
resistance grid bank to 300 amps at
32 volts.

SCOPE SETTINGS

Volts/Div.....................20V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal

NORMAL WELD VOLTAGE WAVEFORM (STICK CC)

MACHINE LOADED TO 300 AMPS AT 32 VOLTS

0 volts

20V

5ms