TROUBLESHOOTING & REPAIR
F-97
F-97
COMMANDER 300
STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.45 – LEAD REMOVAL DETAILS
FILTER
CAPACITOR
FIELD BRIDGE
RECTIFIER
PLUG J30
9.
Disconnect plug J30 at the right front side.
See Figure F.45.
10.
Using the slot head screw driver, discon-
nect leads #200C, #200E(+) and #201B(-)
from the filter capacitor. Label the leads.
11.
Label and remove leads #5P, #201 and
#201A, #200D, and #6H from the field
bridge rectifier. See Figure F.45.
+
5P
#201
#201A
#64
#200D