TROUBLESHOOTING & REPAIR

F-104

F-104

COMMANDER 300

RETEST AFTER REPAIR

Retest a machine:

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machine’s electrical characteristics. OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

Mode

No Load RPM

Load RPM

Low Idle

1350 - 1400

NA

High Idle

1880 - 1919

1780 - 1820

WELDER DC (STICK) OUTPUT

Mode Selector

Fine Control

Open Circuit

Load Volts

Load Amps

Switch

Volts

30-375 Setting

Maximum

82-89

34-38

375-380

PIPE MODES SHORT CIRCUIT CURRENT

(FINE CONTROL AT MAXIMUM)

Selector Position

Short Circuit Current (Amps)

60

80-120

90

180-210

150

280-320

230

380-410

300

380-410

WELDER CV (WIRE) OUTPUT

Mode Selector

Fine Control

Open Circuit

Load Volts

Load Amps

Switch

Voltage

CV Mig/Mag

Maximum

61-64

40-46

370-380

CV Mig/Mag

Maximum

61-64

48-52

20

CV Mig/Mag

Minimum

28-32

11-14

20

AUXILIARY POWER OUTPUT

230 Volt Receptacle

115 Volt Receptacles

Open Circuit

Load Volts

Load Amps

Open Circuit

Load Volts

Load Amps

Voltage

Voltage

230 - 264

216-250

44

115 - 132

108 - 132

15