SPINT

Convert Single-Precision Floating-Point Value to Integer

3-228

Instruction Set

SPRU733

Convert Single-Precision Floating-Point Value to Integer

SPINT

Syntax

SPINT (.unit) src2, dst

.unit = .L1 or .L2

Compatibility

C67x and C67x+ CPU

Opcode

31

29

28

27

23

22

18

17

13

12

11

5

4

3

2

1

0

creg

z

dst

src2

0 0 0 0 0 x 0 0 0 1 0 1 0 1 1 0 s p

3

1

5

5

1

1

1

Opcode map field used...

For operand type...

Unit

src2
dst

xsp
sint

.L1, .L2

Description

The single-precision value in src2 is converted to an integer and placed in dst.

Execution

if (cond)

int(src2) → dst

else

nop

Notes:
1) If src2 is NaN, the maximum signed integer (7FFF FFFFh or

8000 0000h) is placed in dst and the INVAL bit is set.

2) If src2 is signed infinity or if overflow occurs, the maximum signed integer

(7FFF FFFFh or 8000 0000h) is placed in dst and the INEX and OVER
bits are set. Overflow occurs if src2 is greater than 2

31

− 1 or less

than −2

31

.

3) If src2 is denormalized, 0000 0000h is placed in dst and INEX and DEN2

bits are set.

4) If rounding is performed, the INEX bit is set.