Functional Unit Constraints

4-45

Pipeline

SPRU733

Table 4−29 shows the instruction constraints for MPYSP instructions
executing on the .M unit.

Table 4−29. MPYSP .M-Unit Instruction Constraints

Instruction Execution

Cycle

1

2

3

4

MPYSP

R

W

Instruction Type

Subsequent Same-Unit Instruction Executable

MPYSPDP

n

n

n

MPYSP2DP

n

n

n

Instruction Type

Same Side, Different Unit, Both Using Cross Path Executable

Single-cycle

n

n

n

Load

n

n

n

Store

n

n

n

DP compare

n

n

n

2-cycle DP

n

n

n

Branch

n

n

n

4-cycle

n

n

n

INTDP

n

n

n

ADDDP/SUBDP

n

n

n

Legend:

= E1 phase of the single-cycle instruction; R = Sources read for the instruction; W = Destinations written for the

instruction;

n

= Next instruction can enter E1 during cycle