Table 2−7. Control Status Register (CSR) Field Descriptions

Bit

Field

Value

Description

31−24 CPU ID

0−FFh

Identifies the CPU of the device. Not writable by the MVC instruction.

0−1h

Reserved

2h

C67x CPU

3h

C67x+ CPU

4h−FFh

Reserved

23−16 REVISION ID

0−FFh

Identifies silicon revision of the CPU. For the most current silicon
revision information, see the device-specific data manual. Not writable
by the MVC instruction.

15−10 PWRD

0−3Fh

Power-down mode field. See Figure 2−5. Writable by the MVC instruction.

0

No power-down.

1h−8h

Reserved

9h

Power-down mode PD1; wake by an enabled interrupt.

Ah−10h

Reserved

11h

Power-down mode PD1; wake by an enabled or nonenabled interrupt.

12h−19h Reserved

1Ah

Power-down mode PD2; wake by a device reset.

1Bh

Reserved

1Ch

Power-down mode PD3; wake by a device reset.

1D−3Fh

Reserved

9

SAT

Saturate bit. Can be cleared only by the MVC instruction and can be set
only by a functional unit. The set by a functional unit has priority over a
clear (by the MVC instruction), if they occur on the same cycle. The SAT
bit is set one full cycle (one delay slot) after a saturate occurs. The SAT
bit will not be modified by a conditional instruction whose condition is false.

0

Any unit does not perform a saturate.

1

Any unit performs a saturate.

8

EN

Endian mode. Not writable by the MVC instruction.

0

Big endian

1

Little endian