Timer 2

17-11

Keil Simulator

17.3 Timer 2

Timer/Counter 2 is quite different from the two other timers. The operation
mode is determined by the status of one or more of the register bits displayed
in Table 17−1.

Table 17−1.Timer/Counter 2 Control Bits

Register Bit

Toggle Box Name

T2CON.TR2

TR2

T2CON.C/T2

TC/T

T2CON.CP/RL2

CP/RL2

T2CON.EXEN2

EXEN2

T2CON.TCLK

TCLK

T2CON.RCLK

RCLK

Figure 17−6. Timer/Counter 2

The hexadecimal equivalent of the bit pattern created by toggling the individual
bits is displayed in the editable text display, T2CON. Writing a number into this
window will correctly program the states of the respective bit; the same way
it would program the individual bits of the device’s T2CON register.

By the same token, the checked or cleared state of the T2EX, T2 Pin, TF2 and
EXF2 boxes have the same effects on, or are affected the same way by the
P1.T2EX, T2CON.T2, T2CON.TF2 and T2CON.EXF2 pins respectively, as
discussed earlier.

The values and the implications of the contents of the editable text windows
T2 and RCAP2 are consistent with those of the actual device registers in the
MSC1210 system.