Secondary controls, Auto cal, The secondary controls panel – Universal Audio UAD POWERED PLUG-INS ver.6.1 User Manual

Page 159: The secondary controls

Advertising
background image

UAD Powered Plug-Ins Manual

- 159 -

Chapter 12: Ampex ATR-102

Secondary Controls

The secondary controls (

Figure 47

below) adjust the various

calibration, ancillary noise, tone generator, and tape delay
parameters. The secondary controls panel is accessed by
clicking the OPEN button beneath the AMPEX label.

Auto Cal

The Ampex ATR-102 has individual calibration controls for ad-
justing sync (record) EQ, reproduction (playback) EQ, and
record bias, which are used to compensate for the inherent
non-linearities of tape systems. On the hardware, these controls

are typically adjusted to calibrate the system for optimum response compen-
sation due to tape non-linearities whenever the tape type, tape speed, empha-
sis EQ, or head width are changed.

When the Auto Cal (Automatic Calibration) ON button is clicked, the calibra-
tion EQ and bias controls are automatically adjusted to their “flat” calibrated
position for the currently active Tape Type, Tape Speed, Emphasis EQ, and
Head Type. The Auto Cal ON LED illuminates green when the calibration pa-
rameters (Shelf EQ, HF EQ, Repro HF, Repro LF, and Bias) are in their cali-
brated position.

Auto Cal is enabled by default. When Auto Cal is ON, the calibration pa-
rameters (Shelf EQ, HF EQ, Repro HF, Repro LF, and Bias) change values
whenever Tape Type, Tape Speed, Emphasis EQ, or Head Type is modified.
When Auto Cal is OFF, the calibration parameters do not change values
when Tape Type, Tape Speed, Emphasis EQ, or Head Type is modified.

Important:

Any calibration settings made manually are lost when Auto Cal

is activated. Consider saving manual settings as a preset before activating
Auto Cal.

Figure 47. UAD Ampex ATR-102 secondary controls

Advertising
This manual is related to the following products: