Cut filters, Phase, Eq enable – Universal Audio UAD POWERED PLUG-INS ver.6.1 User Manual

Page 359

Advertising
background image

UAD Powered Plug-Ins Manual

- 359 -

Chapter 34: Neve 1081 Equalizer

Cut Filters

The independent low and high cut filters are controlled
by the dual-concentric knobs to the right of the low band
(see

Figure 116 on page 355

). The controls specify the

fixed frequency of the cut filter. The cut filters have an
18 dB per octave slope.

Click+drag the control to change the value, or click the
“silkscreen” frequency values.

Note:

You can also click the high cut/low cut symbols below the knob to cycle

through the available values, or shift + click to step back one frequency.

High Cut

The inner (blue) dual-concentric knob controls the high cut filter. The available
frequencies for the high cut filter are 18 kHz, 12 kHz, 8.2 kHz, 5.6 kHz, 3.9
kHz, and OFF. When OFF is specified, the high cut filter is disabled. UAD
CPU usage is not reduced when OFF.

Low Cut

The outer (silver) dual-concentric ring controls the low cut filter. The available
frequencies for the low cut filter are 27 Hz, 47 Hz, 82 Hz, 150 Hz, 270 Hz,
and OFF. When OFF is specified, the low cut filter is disabled. UAD CPU us-
age is not reduced when OFF.

Phase

The Phase (PH) button inverts the polarity of the signal. When the
switch is in the “In” (lit) position, the phase is reversed. Leave the
switch in the “Out” (unlit) position for normal phase.

EQ Enable

The equalizer is engaged when the EQ switch is in the “In” (lighted)
position. To disable the EQ, put the switch in the “Out” (unlit) position.
Click the button to toggle the state.

In the hardware 1081, the audio is still slightly colored even when the EQ
switch is in the Out position. This is due to the fact that the signal is still pass-
ing through its circuitry. Therefore, the signal will be slightly colored when this
switch is in the Out position. UAD DSP usage is reduced when the EQ is by-
passed with this control (unless

“UAD-2 DSP LoadLock” on page 74

is en-

abled). If a true bypass is desired, use the OFF position of the

“Input Gain” on

page 355

control.