UAD Powered Plug-Ins Manual

- 363 -

Chapter 35: Neve 31102 Console EQ

Midrange Band

The midrange band is controlled by dual-concentric
knobs, delivering smooth semi-parametric midrange
equalization with a choice of two bandwidths. The
inner knob controls the band gain, and the outer
ring selects the frequency or band disable.

Midrange Gain

The equalization gain for the midrange band is selected with the inner knob
of the dual-concentric control. The available range is approximately ±15 dB.
The gain value is zero when the knob position indicator is pointing straight
down.

Midrange Frequency

The midrange frequency is specified with the outer ring of the dual-concentric
knob controls. The ring knob pointer can be dragged with the mouse, or click
the peak/dip symbol above the knob to cycle through the available frequen-
cies (shift+click to step back one frequency).

The available midrange center frequencies are 7.2 kHz, 4.8 kHz, 3.2 kHz,
1.6 kHz, 0.7 kHz, 0.35 kHz, and off. When off is specified, the band is dis-
abled. UAD DSP usage is not reduced when the band is off.

High Q Select

The High Q button switches the response of the midrange band from
“normal” to a narrower bandwidth for a sharper EQ curve. The band is
in normal mode by default; it’s in high Q mode when the button is

“down” (darker).

Low Shelf

The low band is controlled by dual-concentric knobs, deliv-
ering smooth shelving equalization. The inner knob con-
trols the band gain, and the outer ring selects the frequency
or band disable.

Low Gain

The equalization gain for the low band is selected with the

inner knob of the dual-concentric control. The available range is approxi-
mately ±15 dB. The gain value is zero when the knob position indicator is
pointing straight down.