0 installation – Alpha Technologies XM3-HP Series - Technical Manual User Manual

Page 47

Advertising
background image

47

017-882-B0-001 Rev. C2 (10/2013)

2.0

Installation

2.2

XM3-HP Start-Up Procedure, continued

2.2.7 Communications DOCSIS Status Monitoring, continued

2.0

Installation, continued

Verify the DSM3 LEDs behavior is as follows:

Refer to Step 4 in the above table for normal LED behavior when the DSM3 is fully functional.

• Blue Rx/Tx Power LED indicates Rx/Tx Power at a warning level. Make the necessary RF level

adjustments.

• Red Rx/Tx Power LED indicates Rx/Tx Power at an alert level. Make the necessary RF level

adjustments.

LEDs and Indications (20)

Step

Communications State

ALM/RDY Downstream (DS) Registration (REG) Rx/Tx Power

Communications (COM)

1

Transponder Initializing/Searching

for Downstream DOCSIS channel

Flashing

(Green)

Flashing

OFF

OFF

Flashing

2

DOCSIS Channel locked -

Completing upstream and network

registration

Flashing

(Green)

ON

Flashing

ON (Green)

Flashing

3

Online - Registration Complete

Flashing

(Green)

ON

ON

ON (Green)

Flashing

4

DSM3 Series fully functional

Flashing

(Green)

ON

ON

ON (Green)

Bursts when Communicating

LED Color

Rx Range (dBmV)

Tx Range (dBmV)

Green

+10 to -10

0 to +50

Blue

+15 to +10 and -10 to -15

+50 to +55

Red

>+15 and <-15

>+55

2.2.7.2 LED Status Verification

Table 2-1, DSM3 LEDs Behavior

Advertising