017-882-B0-001 Rev. C2 (10/2013)

2.0

Installation

2.2

XM3-HP Start-Up Procedure, continued

2.2.9 Local Verification of DOCSIS Transponder

2.0

Installation, continued

To confirm successful hardware installation before leaving the installation site, verify network

connectivity and correct hardware interconnection.
The DS and REG LEDs on the front of the DSM3 Series should be ON solid green. This indicates

successful registration with the headend. In addition, the RF LED should also be ON solid green indi-

cating proper RF power levels and the ALM/RDY LED should be blinking green for normal operation.

With the DSM3 Series used in conjunction with the XM3-HP Power Supply, network connectivity can

be verified via the COMM menu on the XM3 Smart Display. Figure 2-28 provides a list of parameters

available on the XM3 Smart Display populated with sample values.

COMM - GENERAL
COMM - EXTENDED
COMM - DIAGNOSITCS

ENTR

ESC

COMM - GENERAL
CM MAC ADDRESS

00:90:EA:A0:04:99

ESC

COMM - EXTENDED
DSM MODEL/CONFIG

DSM3x CW - 8B

ESC

COMM - DIAGNOSTICS
CABLE MODEM STATUS

Operational

ESC

COMM GENERAL

CM MAC ADDRESS

00:90:EA:A0:04:99

CM IP ADDRESS

192.196.203.101

CM IPV6 ADR PREFIX*

2001:123:456:789

CM IPV6 ADR POSTFIX*

111:222:333:3434

CPE MAC ADDRESS**

00:90:EA:A0:04:9A

CPE IP ADDRESS**

192.168.200.100

CM RECEIVE POWER

-12.9dBmV

CM TRANSMIT POWER

34.5dBmV

DOWNSTREAM SNR

33.8dB

COMM - EXTENDED

DSM MODEL/CONFIG

DSM3X CW-8B

DSM FIRMWARE VERSION

4.4.9.0_03.02_NA

SYSTEM NAME

ABC123 CABLE

SYSTEM CONTACT

JOHN DOE

SYSTEM LOCATION

123 BAKERVIEW

COMMON LOGICAL ID

12345-3767 ALPHAWAY

DOCSIS CONFIG FILE

ALPHA_DSM3.CM

DSM SERIAL NUMBER

A00499

SYSTEM DEVICES 3-7*

IPU-1 SAG-1 DOC-1

SYSTEM DEVICES 6-7*

XM3-1 APP-1 BTQ-1

SYSTEM DEVICES 7-7*

UTL-1

CABLEWARE SERVER IP

192.168.200.151

COMM - DIAGNOSTICS

CABLE MODEM STATUS

OPERATIONAL

SYSTEM UPTIME

3 DAYS 05H:16M:59S

DOWNSTREAM FREQUENCY

300.000 MHZ

DOWN MODULATION TYPE

256 QAM

UPSTREAM FREQUENCY

15.000 MHZ

T3 TIMEOUTS

80360

T4 TIMEOUTS

51

CODEWORD ERROR RATIO

8.20%

MICROREFLECTIONS

-5 DBC

CM RESETS

10

CM LOST SYNCS

5

LAST SNMP QUERY

Date/Time

COMM-DIAGNOSTICS
CABLE MODEM STATUS

OPERATIONAL

ESC

COMM-EXTENDED
DSM MODEL/CONFIG

DSM3X CW-BB

ESC

*

Menu item available if

DSM3 is provisioned in

IPv6 mode

**

Menu item available if

DSM3 is provisioned in

Dual-IP mode

*

Menu item will populate

for only Cableware

configured units

NOTE: System Device menu items

are internal Alpha diagnostic codes.

The System Devices menu items will

populate based on the option cards

(SAG, APP, DOC) installed and the

number of external devices added to a

power system such as multiple XM3s

and/or AlphaGen.

COMM - FAULT
RF POWER LEVEL FAULT

SEE GENERAL MENU

ESC

NOTE:

COMM-FAULT Menu

appears only if there is no RF

connection or RF interruption

occurs.