System connect considerations – Biamp A4 User Manual

Page 186

Advertising
background image

Audia-Manual-A4

The computer must be assigned an IP address (under Network Card Settings>Properties). Most
computers set TCP/IP address automatically, but Audia

devices require manual assignment.

Initially, the computer IP address should be assigned as 192.168.1.X (where range of X =
1~254). Each Audia

device must also be assigned a unique IP address (see

Device

Maintenance

). The factory default IP address for all Audia devices is 192.168.1.101.

Many system designs require only a single Audia

device. These would be systems where the

number of inputs/outputs, and the amount of DSP processing, does not exceed that of a
standard configuration (see

Hardware

). When a single unit is used, network considerations are

simplified. A 'non-CobraNet' unit may be used, and no Ethernet switch is required. Therefore, all
CobraNet connections, and most Ethernet connections go away, as well. The only Ethernet
connection is that between the computer and the Audia

device ('cross-over' CAT5 cable). A

'cross-over' cable is included with each Audia

device.

System Connect Considerations

166

Advertising