System Control

SET 1 AECNLP 24 3 None

3

<LF>

Result: SET 1 AECNLP 24 3 3 <LF>

Analog Outputs

Attribute

Commands

Index

Value Range

Output

Level

OUTLVL

SET, SETL, GET, GETL, INC,
DEC

2

-100 ~ 0 *

Output

OUTMUTE

SET, GET

2

0 = unmuted

1 = muted

Output Full

Scale Level **

OUTFS

SET, SETL, GET, GETL

2

-31, 0, 6, 12, 18, 24

Invert

Polarity

OUTINVRT

SET, GET

2

0 = normal

1 = inverted

Mic Level

Pad ***

OUTPAD

SET, GET

2

0 = off

1 = on

* Can contain a decimal number.

** Supported only on FLEX OP-2e cards (-31 & 24 values supported on SOLO 4x12 outputs 1~4).

*** Supported on all FLEX output cards (and SOLO 4x12 outputs 1~4).

Example: Set Device 2 Output Mute at Instance ID 3, Output 4 to muted.

Command

Dev #

Attribute

Inst ID

Index 1

Index 2

Value

Line Feed

SET 2

OUTMUTE 2 None 4

1

<LF>

Result: SET 2 OUTMUTE 3 4 1 <LF>

Power Amp

Attribute

Commands

Index

Value Range

Mute

AMPMUTE

SET, GET

2

0 = unmuted

1 = muted

Invert

AMPINVRT

SET, GET

1

0 = normal

191