Level control, Logic control, Audio wiring diagrams – Biamp A4 User Manual

Page 29

Advertising
background image

Introduction

All programmed panel functions are assigned using the control dialog box, which is produced by double-clicking the RED-
1 block.

A list displays all defined control items, each with a Channel Number and customizable Control Label. The New button
creates a control item in the list, and the user is prompted to either accept the default label or enter a new one. Rename
allows the user to change the Control Label of the selected control item. Delete removes the selected control item from
the list. Move Up and Move Down modify the order of the control items in the list, giving the user the ability to control the
display order of the control items on the RED-1 panel.

Each control item may have a Level Control assignment, a Logic Control assignment, or both.

Level Control

Object Code selects from a list of blocks found in the layout, and the Instance ID is entered automatically, if known.
Control ID selects from a list of available levels within the chosen block.

Logic Control

Logic Index specifies which logic connection point, if any, on the RED-1 block will be triggered when that control item is
selected.

Once the RED-1 block has been programmed with control items, the Select and Up/Down Arrow buttons at the bottom of
the control dialog box may be used to mimic how the control will function from the physical panel.

Control dialog boxes for RED-1 devices may be minimized to create user control surfaces (see Customizing Component
Objects).

Audio Wiring Diagrams

9