Equalizer blocks, Cobranet ip address – Biamp A4 User Manual

Page 220

Advertising
background image

Audia-Manual-A4

Result: SET 1 RMCMBWALL 4 2 1 <LF>

Mix-Minus Combiner

Attribute

Commands

Index

Value Range

Group State

MCMBGROUP

SET, GET

1

0 ~ 32

Note

: Index1 is the input being addressed. Value is the group; this is represented by a letter in

Audia software, but addressed as a number in ATP commands. (Example: ungroup=0, A=1, B=2,
C=3….)

Equalizer Blocks

Graphic EQ

Attribute

Commands

Index

Value Range

EQ Band Level

GEQLVLBND

SET, SETL, GET, GETL, INC,
DEC

1

-30 ~ 15 *

Bypass All Bands

GEQBYPALL

SET, GET

None 0 = active

1 = bypassed

* Can contain a decimal number.

Note:

Index1 represents the filter to be controlled. Graphic EQ filters are numbered from left to

right, and the selected band is displayed in the upper left hand corner of the Graphic EQ dialog
screen in Audia software. Use this number as Index1 for Graphic EQ strings.

Example: Set Device 2 Graphic EQ Bypass All Bands at Instance 9 to bypass.

Command

Dev #

Attribute

Inst ID

Index 1

Index 2

Value

Line Feed

SET 2

GEQBYPALL 9 None

None

1

<LF>

Result: SET 2 GEQBYPALL 9 1 <LF>

Parametric EQ

Attribute

Commands

Index

Value Range

EQ Bandwidth

PEQBWBND

SET, SETL, GET, GETL

1

0.010 ~ 4.000 *

Bypass EQ Band

PEQBYPBND

SET, GET

1

0 = active

1 = bypassed