System Control

Result: GET 2 XOVR3FC 40 1 <LF>

Dynamics Blocks

Leveler

Attribute

Commands

Index

Value Range

Bypass

LVLRBYP

SET, GET

None 0 = active

1 = bypassed

Comp/Limiter

Attribute

Commands

Index

Value Range

Bypass

CLIMBYP

SET, GET

None 0 = active

1 = bypassed

Ducker

Attribute

Commands

Index

Value Range

Input Level

DKRLVLIN

SET, SETL, GET, GETL

None -100 ~ 12 *

Level Sense

DKRLVLSENSE

SET, SETL, GET, GETL

None -100 ~ 12 *

Bypass Ducker

DKRBYP

SET, GET

None 0 = active

1 = bypassed

Mute Sense

DKRMUTESENSE

SET, GET

None 0 = unmuted

1 = muted

Input Mute DKRMUTEIN

SET,

GET

None

0 = unmuted

1 = muted

Logic In Enable

DKRENLOGIN

SET, GET

None 0 = disabled

1 = enabled

Logic Out Enable

DKRENLOGOUT

SET, GET

None 0 = disabled

1 = enabled

Logic Input Invert

DKRINVLOGIN

SET, GET

None 0 = normal

1 = inverted

Logic Output Invert

DKRINVLOGOUT

SET, GET

None 0 = normal

1 = inverted