Equipment table, Equipment, Table – Biamp A4 User Manual

Page 84

Advertising
background image

Audia-Manual-A4

NOTE: You must first

Send Configuration

to a device before a Password can be assigned.

Passwords cannot be assigned to non-configured devices or design layouts.

Equipment Table

Provides an editable table of Audia® devices in the system design. Add and Remove can be
used to manually change the hardware design. However,

Compile

will add devices if needed

(but will not automatically remove unnecessary devices). The Equipment Table may be used to
aid system design, by initially specifying desired hardware configurations. Serial # and Device
Description Label appear only when connected to a system, at which time the Equipment Table
becomes 'read-only' information. CN Latency allows the selection of reduced delay times, which
are supported on newer CobraNet® firmware versions. The default CobraNet Latency for new
DAP files is 5.33mS (see

Compile Options

). Alternate choices of 2.67mS and 1.33mS are

available (see

System Network Considerations

). CN Latency affects the creation of new DAP

files, as well as the modification and recompilation of existing files/systems.

An I/O tab at the lower-left of the Equipment Table dialog box provides a list of input/output
cards installed in the chassis listed above. For AudiaFLEX this will be a series of 2-channel
input (IP-2, AEC-2HD, & TI-2) and 2-channel output (OP-2e & PA-2) cards (any combination up
to a total of 12 cards or 24 channels). For standard Audia and AudiaSOLO this will be a single
card expressing the complete I/O configuration (8x8, 12x4, or 4x12).

64

Advertising