Delay blocks – Biamp A4 User Manual

Page 227

Advertising
background image

System Control

Result: SET 1 RTRMUTEXP 98 4 5 0 <LF>

Source Selection

Attribute

Commands

Index

Value Range

Source

SRCSELSRC

SET, GET, SETD, GETD

2

0 = No Source/muted

1 = Source 1

2 = Source 2

3 = Source 3

Level SRCSELLVL

SET, GET, SETL, GETL, SETD,
GETD

1

-100 ~ 12

Example: Set Device 1 Source Selection Source at Instance 99 Source 2 selected.

Command

Dev #

Attribute

Inst ID

Index 1

Index 2

Value

Line Feed

SET 1

SRCSELSRC

99 None 1

2

<LF>

Result: SET 1 SRCSELSRC 99 1 2 <LF>

Example: Set Device 1 Source Selection Volume at Instance 99 to -54 dB for source input 3.

Command

Dev #

Attribute

Inst ID

Index 1

Index 2

Value

Line Feed

SET 1

SRCSELLVL

99 3 None -54

<LF>

Result: SET 1 SRCSELLVL 99 3 -54<LF>

In this example, Index 1 represents the input source, where in the previous example, Index 1 represents the output
channel.

Delay Blocks

Delay

Attribute

Commands

Index

Value Range

Delay in Milliseconds

DLYMSEC

SET, SETL, GET, GETL

None 0 ~ block maximum *

Delay in Centimeters

DLYCM

SET, SETL, GET, GETL

None 0 ~ block maximum *

207