Device maintenance dialog box, Device maintenance – Biamp A4 User Manual

Page 62

Advertising
background image

Audia-Manual-A4

Device Maintenance Dialog Box

Device Information

provides information (such as firmware version, input/output configuration,

etc.) regarding the selected device.

Set Date/Time

allows update of the internal real-time clock,

and sycronization to an external PC/server.

Set IP Address

assigns a device IP Address such as

192.168.1.X

(where range of X = 1~254). The factory default IP Address is 192.168.1.101.

However, IP Addresses cannot be duplicated, even in simple (Audia® only) networks, and must
be carefully managed when network topology is more complex. Set Device Description allows
the selected device to be given a descriptive name. Serial Port Setting selects the baud rate for
RS-232 communications (default 38,400) and allows responses to ATP commands to be
suppressed. Reset/Initialize clears all current system design data from the selected device. This
happens automatically whenever a new system design file (.DAP) is uploaded (see

Send

Configuration

).

Update Firmware

produces a file browser window.

42

Advertising