Filter blocks, Index – Biamp A4 User Manual

Page 221

Advertising
background image

System Control

Center Freq.

PEQFCBND

SET, SETL, GET, GETL, INC,
DEC

1

20 ~ 20000

EQ Band Level

PEQLVLBND

SET, SETL, GET, GETL, INC,
DEC

1

-30 ~ 15 *

Bypass All Bands

PEQBYPALL

SET, GET

None 0 =active

1 = bypassed

* Can contain a decimal number.

Note:

Index1 represents the filter to be controlled. Parametric EQ filters are initially numbered

from left to right, and the selected band is displayed in the upper left hand corner of the
Parametric EQ dialog screen in Audia software. Use this number as Index1 for Parametric EQ
strings.

Example: Increment Device 1 Parametric EQ Band Level at Instance 11 Band 2 by 2dB.

Command

Dev #

Attribute

Inst ID

Index 1

Index 2

Value

Line Feed

INC 1

PEQLVLBND

11 2 None

2

<LF>

Result: INC 1 PEQLVLBND 11 2 2 <LF>

Feedback Suppressor

Attribute

Commands

Index

Value Range

Reset All Filters

FBSRESET

SET

None None

Fix All Filters

FBFIXALL

SET, GET

None 0 = not fixed

1 = fix all

Example: Set Device 1 Feedback Suppressor Reset All Filters at Instance 4.

Command

Dev #

Attribute

Inst ID

Index 1

Index 2

Value

Line Feed

SET 1

FBSRESET 4 None

None None <LF>

Result: SET 1 FBSRESET 4 <LF>

Filter Blocks

HPF

Attribute

Commands

Index

Value Range

201