Crossover blocks – Biamp A4 User Manual

Page 223

Advertising
background image

System Control

SET 1

HSFLTGAIN

100

None

None -10

<LF>

Result: SET 1 HSFLTGAIN 100 –10 <LF>

All-Pass Filter

Attribute

Commands

Index

Value Range

Bandwidth

APFLTBWBND

SET, SETL, GET, GETL

1

0.01 ~ 4.0 *

Center Freq.

APFLTFCBND

SET, SETL, GET, GETL

1

20 ~ 20000 *

Filter Bypass

APFLTBYPBND

SET, GET

1

0 = active

1 = bypassed

Filter Bypass

APFLTBYPBND

SET, GET

1

0 = active

1 = bypassed

Bypass All

APFLTBYPALL

SET, GET

None 0 =active

1 = bypassed

* Can contain a decimal number.

Note:

Index1 represents the filter band to be controlled. All-Pass Filter bands are initially

numbered from left to right, and the selected band is displayed in the upper left hand corner of the
All-Pass Filter dialog screen in Audia software. Use this number as Index1 for All-Pass Filter
strings.

Crossover Blocks

2-Way

Attribute

Commands

Index

Value Range

Cut-Off Freq.

XOVR2FC

SET, SETL, GET, GETL

1

20 ~ 20000

* Can contain a decimal number.

3-Way

Attribute

Commands

Index

Value Range

Cut-Off Freq.

XOVR3FC

SET, SETL, GET, GETL

1

20 ~ 20000

* Can contain a decimal number.

4-Way

Attribute

Commands

Index

Value Range

203