Biamp A4 User Manual

Page 212

Advertising
background image

Audia-Manual-A4

Polarity

1 = inverted

Gain

AMPGAIN

SET, SETL, GET, GETL, INC,
DEC

2

0 ~ 24

Clip Limiter

AMPCLIPLIM

SET, GET

2

0 = disabled

1 = enabled

Impedance

AMPIMPED

SET, GET

2

1 = 4 ohm

2 = 6 ohm

3 = 8 ohm

4 = auto

Networked

Paging Station-1

Attribute Commands

Index

Value

Range

Level NPSLVL

SET, SETL, GET, GETL, INC,
DEC

None -100 ~ 12 *

Mute

NPSMUTE

SET, GET

None 0 = unmuted

1 = muted

* Can contain a decimal number.

TI-2 Dialer

Attribute

Commands

Index

Value Range

Caller ID

TICID

GET

None

None

Full User Caller ID

TICIDUSER

GET

None

None

Hook-Flash TILINE FLASH

None

None

Hook-Switch

State

TIHOOKSTATE

SET, GET

None

0 = off-hook

1 = on-hook

Speed Dial

Tel. Number

TISDENTRY

SET, GET

1

enter the phone

number

Speed Dial

Name

TISDLABEL

SET, GET

1

enter the name

Last Number

Dialed

TILASTNUM GET

None

None

192