Perating, Tructure, Ppendix – Burkert Type 8635 User Manual

Page 165

Advertising
background image

8635 - 163

O

PERATING

S

TRUCTURE

(A

PPENDIX

)

For each message applies:

F1 – [

HELP]: call up a Help text to explain the current HART

parameter

F2 – [

PREV]: scroll backward

F3 – [

NEXT]: scroll forward

F4 – [

EXIT]: quit menu

1

Only with version with process controller.

2

Only with version with APR (Analog Position Repeat)

3

Only with

CHARACT = free

4

Menu item only present when

SETPOINT = external has been set in menu item P-CONTROL.

5

Menu item only present when

P.CO TUNE = activated has been set in menu item P-CONTROL.

6

Menu item only present when

P.INP = ON has been set in menu item SIGNAL ERROR.

7

Menu item only present when Binary Out 1 =

DEV.X or = LIM.X has been set in menu item OUTPUT.

8

Menu item only present when Binary Out 2 =

DEV.X or = LIM.X has been set in menu item OUTPUT.

9

Menu item only present when

P-CONTRL = ON has been set in menu item ADD FUNCTION.

1 Day

Î entry mask

8 alphanumeric characters

2 Descriptor

Î entry mask

16 alphanumeric characters

3 Date

Î

entry mask for date

4 Message

Î entry mask,

32 alphanumeric characters

5 Final assembly num.

Î

entry mask
value between 0 and 99999999

For each message applies:

F1 – [HELP] call up a Help
text to explain the current
HART parameter

F2 – [SEND] send all altered
HART parameters to SIDE
Control (after quitting the
entry mask)

2 Device setup

Model

8 HART parameters

1 Device information

8635

Distributor

...

Manufacturer

Bürkert ...

Dev. Id.

0

TAG

...

Descriptor

...

Message

...

Date

01/01/02

Final assembly num.

0

Universal rev.

5

Field dev. rev.

2

Software rev.

16

Poll addr.

0

Num req. Preams

5

1 Tag

2 Descriptor

3 Date

4 Message

5 Final assembly num.