Updating e645xx receiver firmware – Agilent Technologies Agilent E6474A User Manual

Page 120

Advertising
background image

120

Agilent E6474A User’s Guide

6

Get Assistance, if You Need It

Updating E645xx Receiver Firmware

1 In the System Setup view, configure a receiver measurement

view. Once data logging starts, the E6474A software
determines if the Agilent E645xx digital receiver has the
correct firmware. If not, the message box in

Figure 2

appears.

2 Click Yes. The message box in

Figure 56

appears.

NOTE

If your hardware configuration includes daisy-chained E645xx receivers,
you must first disconnect the receivers, then connect one receiver at a
time, and upgrade the firmware on each receiver. When you are finished
updating the firmware, reconnect the daisy-chain, and reconfigure the
daisy-chained receivers.

Figure 55

Firmware upgrade required, first dialog box

Advertising