Specifications – Agilent Technologies Agilent E6474A User Manual

Page 152

Advertising
background image

152

Agilent E6474A User’s Guide

C

System Information

E6452A Option 002/E6457C Japan cellular band receiver specifications

Item

Description

Specification

Frequency

Frequency range

832 to 870 MHz 887 to 925 MHz

Frequency accuracy With GPS time
synchronization

±1 ppm
±0.05 ppm, characteristic

IF bandwidth

1.25 MHz, characteristic
30 kHz, characteristic

Aging of TCXO

±1 ppm/year

Amplitude

Accuracy, 1.25 MHz IF

±1 dB from – 40 dBm to – 100 dBm (20° to 30°C)
±2 dB from – 50 dBm to – 100 dBm (0° to 55°C)
±3 dB from – 40 dBm to – 50 dBm (0° to 55°C)

Accuracy, 30 kHz IF

±1.5 dB from – 40 dBm to – 100 dBm (20° to 30°C)
±2.5 dB from – 40 dBm to – 100 dBm (0° to 55°C)

Noise figure

8.0 dB typical

Maximum safe input level

+10 dBm, 20V DC, characteristic

1 dB compression point

*

– 15 dBm, characteristic

Adjacent channel desensitization

Adjacent channel rejection

Internally generated spurious, input
referred

– 25 dBm typical
45 dB typical
– 120 dBm

Input/Output

RF input

50

Ω Type-N

Connectors

Computer

RS-232 (DB9) Male

GPS

RS-232 (DB9) Male

Power

DC power jack 100 mils, positive center

Miscellaneous

Operating temperature range

0°C to 55°C

Maximum relative humidity

80% for temperatures up to 31°C, decreasing linearly
to 50% relative humidity at 40°C

Storage temperature range

– 40°C to +70°C