Commands and queries by subsystem, Acquisition - controlling waveform captures, Cursor - performing measurements – Teledyne LeCroy WaveAce 1000_2000 Remote Control User Manual

Page 14: Waveace remote control

Advertising
background image

WaveAce Remote Control

Commands and Queries by Subsystem

Acquisition - Controlling Waveform Captures

Short Form

Long Form

What the Command/Query Does

*TRG

*TRG

Executes an ARM command.

ACQW

ACQUIRE_WAY

Specifies the acquisition mode.

ARM

ARM_ACQUISITION

Changes acquisition state from stopped to single.

ASET

AUTO_SETUP

Adjusts vertical, timebase and trigger parameters.

ATTN

ATTENUATION

Selects the vertical attenuation factor of the probe.

BWL

BANDWIDTH_LIMIT

Enables/disables bandwidth-limiting low-pass filter.

CPL

COUPLING

Selects the specified input channel's coupling mode.

FRTR

FORCE_TRIGGER

Forces the instrument to make one acquisition.

ILVD

INTERLEAVED

Enables/disables Random Interleaved Sampling (RIS).

OFST

OFFSET

Allows output channel vertical offset adjustment.

PDET

PEAK_DETECT

Enables or disables built-in peak detection function.

STOP

STOP

Immediately stops signal acquisition.

TDIV

TIME_DIV

Modifies the timebase setting.

TRCP

TRIG_COUPLING

Sets the coupling mode of the specified trigger source.

TRDL

TRIG_DELAY

Sets the time at which the trigger is to occur.

TRLV

TRIG_LEVEL

Adjusts the trigger level of the specified trigger source.

TRMD

TRIG_MODE

Specifies the trigger mode.

TRSE

TRIG_SELECT

Selects the condition that will trigger acquisition.

TRSL

TRIG_SLOPE

Sets the trigger slope of the specified trigger source.

VDIV

VOLT_DIV

Sets the vertical sensitivity.

WAIT

WAIT

Prevents new analysis until current is completed.

Cursor - Performing Measurements

Short Form

Long Form

What the Command/Query Does

CRMS

CURSOR_MEASURE

Specifies the type of cursor/parameter measurement.

CRST

CURSOR_SET

Allows positioning of any cursor.

CRVA?

CURSOR_VALUE?

Returns trace values measured by specified cursors.

PACU

PARAMETER_CUSTOM

Controls parameters with customizable qualifiers.

PAVA?

PARAMETER_VALUE?

Returns current parameter, mask test values.

12

920836 Rev B

Advertising