Device Emulation (Optional)

133

Define Endpoint

A Device allows up to a total of seven endpoints under defined alternative
settings. You can add endpoints by clicking an alternative setting then the Add
Endpoint
button.
To define the endpoints, select an endpoint and click the Endpoint Descriptor
button to display the Endpoint Definition dialog, shown in Figure 101.

Figure 101 Endpoint Definition Dialog

Transfer Type

Click the down arrow next to the Transfer Type item
list and choose Isochronous, Bulk or Interrupt.

Data Direction

Click the down arrow next to the Data Direction item
list and choose IN or OUT.

Data (Hex)

For transfer types using data, enter data values in hex
or choose from pre-defined data by clicking the down
arrow next to the Data(Hex) item list and making a
choice.

Packet Size

Enter a packet size (bytes/packet) for the device to
returned. (Default is 64.) Data returns to the Host in
N bytes/packet increments.

Buffer Size

Enter a buffer size in bytes. (Default is 512). This
defines how much data the endpoint can accept.

ACK Termination Ratio

Defines the number of NAKs returned before an ACK
is returned. (Default is 1)

Endpoint Reply Time (bit)

Enter a delay time between the Host packet and the
Conquest M2 Device reply packet.

Handshake Type

Click the down arrow next to the Handshake Type and
choose an appropriate response type. This defines
the response of the Conquest M2 Device for the
selected endpoint.