Teledyne LeCroy Conquest User Manual - Users Manual User Manual

Page 45

Advertising
background image

Protocol Analysis

35

3. If known, you can specify a Device address (in hex) and an endpoint

address (in binary) by making the appropriate entries in the Dev Addr
and Endpoint text box.

Figure 12 Trigger Choices in High Speed Mode

4. Choose up to three Data Capture selections from the three available

Data Capture drop-down list boxes. Table 5 on page 44 lists the
available selections. The capture selections are different for High speed
and Full/Low speed operation. All capture selections, however, are
available when the Analyzer is set to operate in the Auto Speed mode
(only in Conquest M2).

Figure 13 Data Capture Choices in High Speed Mode

To exclude NAK, NYET Transactions and/or SOF, Keep Alive Events, check
the corresponding check box. These are filtered in real time by the hardware
without using memory resources.

5. Click Run to capture and trigger immediately and wait for the results to

display, as shown in Figure 14.

Advertising