230

INPUTDATA

INPUTDATA

Remark:

The INPUTDATA is a symbolic representation of the entire data stream that is
passed to the decoder.

Find

Find (StartBit, Pattern)

Remark:

The function searches for a data pattern in the data stream. It returns the bit
location of the first instance of the data pattern, or the value equivalent to
LengthOf(INPUTDATA+1) if the data pattern is not found.

Input Parameters:

StartBit:

Specifies a zero-based start position of the field in the
data, in bits. This parameter can be an integer or an
expression.

Pattern:

Identifies the data pattern for which to search. This
parameter can be an integer or an expression.

LengthOf

LengthOf (DataId | INPUTDATA )

Remark:

The function returns the length of data in bits

Input Parameters:

DataId

Identifier that specifies data block. This identifier is the
output of a GetData statement.

INPUTDATA:

The INPUTDATA function.

Example:

/* Add unknown field if excess data detected. Demonstrates use of EOD,

CURPOS, LengthOf, and INPUTDATA functions */

if (not EOD)

{

Unexpected = AddField(CURPOS,

LengthOf(INPUTDATA) – CURPOS,

"Unexpected","Unexpected Data",

"Unexpected");

}