Probe command warnings

Symptom - When running any of the probe commands, the following message is
displayed:

!

CAUTION:

CAUTION:

Do not continue. Answer n. Do not answer y.

Solution - To recover from this condition:

1. Enter: n

This stops the probe command.

2. Enter the following commands:

setenv auto-boot? false

reset-all

3. It is now safe to run any of the probe commands and perform any other boot

PROM-level diagnostics.

4. After you finish probing the system devices, enter the following commands:

!

CAUTION:

CAUTION:

If you fail to enter these commands, any reboots that you do in the future will
stop at the boot prompt instead of proceeding through the normal boot-up
process.

setenv auto-boot? true

boot -r

The system reboots.

This command may hang the system if a Stop-A or halt command has

been executed. Please type reset-all to reset the system before

executing this command. Do you wish to continue [Y/N].