94 Avaya CMS Sun Fire V880 Computer Hardware Installation, Maintenance, and Troubleshooting

Replacing the RSC card

This section shows how to replace an RSC card. The RSC card is located below the nine
PCI card slots on the I/O board. It is labeled "RSC" on the rear panel of the computer.

!

DANGER:

DANGER:

The system supplies hazardous voltage to the RSC card even when the
system is turned off. To avoid personal injury or damage to the RSC card,
you must disconnect the AC power cords before servicing the RSC card.

This section includes the following topics:

Required references

on page 94

Replacing the RSC card

on page 94

Required references

For additional information about replacing the RSC card, see Sun Fire 880 Server Service
Manual
at the Sun documentation Web site:

http://docs.sun.com

Replacing the RSC card

To replace the RSC card:

1. Log in to the system as root.

2. Enter:

/usr/sbin/shutdown -y -i0 -g0

This shuts down the system.

3. Press and release the front panel power button to turn off the system.

Wait for the front panel Power/OK LED to turn off.