Setting up the interfaces – ADTRAN 600R User Manual

Page 172

Advertising
background image

Section 4 User Interface Guide

Total Access 600 Series System Manual

170

© 2004 ADTRAN, Inc.

61200624L1-1B

The following example provides step by step instructions for configuring the Total Access 6XX T1 ATM
system (

I

NTERFACES

and

L2 P

ROTOCOL

) for a standard voice application. System Info and System Config

parameters should be set according to your system need. Refer to System Info on page 49 and System
Config
on page 51
for more details.

1. Setting up the Interfaces

For more details on the configuration parameters discussed in this section, refer to the following pages:

Network T1 menus beginning on

page 71

FXS menus beginning on

page 82

T1 Interface Setup Instructions

Step

Action

1

From the main menu, select I

NTERFACES

.

2

Highlight the C

ONFIG

menu for the T1 interface and press <E

NTER

>.

3

Right arrow to select F

ORMAT

and choose ESF or SF.

This format must match the format used by the other units in the
network.

4

Set the L

INE

C

ODE

to B8ZS or AMI.

This line code must match the line code used by the other units in the
network.

5

Set the E

QUALIZATION

or line build out. The default setting of 0

D

B is

usually sufficient.

6

Set the CSU L

PBK

option to E

NABLE

, D

ISABLE

, or D

ISABLE

A

LL

based on

whether looping to this unit from another unit will be allowed.

Advertising
This manual is related to the following products:

604, 624, 612, 606, 616