ADTRAN 600R User Manual

Page 60

Advertising
background image

Section 4 User Interface Guide

Total Access 600 Series System Manual

58

© 2004 ADTRAN, Inc.

61200624L1-1B

S

YSTEM

C

ONFIG

> S

YSLOG

> S

YSLOG

IP

IP address of the syslog daemon to which log message should be sent. The values must be dotted decimal
notation.

S

YSTEM

C

ONFIG

> S

YSLOG

> S

YSLOG

F

ORMAT

The

S

YSLOG

F

ORMAT

is the format of log messages. "

A

DTRAN

" uses a format that is compatible with

ADTRAN Utilities and forces the Syslog Facility to LOCAL0.

U

NIX

uses the traditional Unix format and

reports at the configured facility level.

S

YSTEM

C

ONFIG

> S

YSLOG

> S

YSLOG

F

ACILITY

The choices are:

L

OCAL

0

,

L

OCAL

1

,

L

OCAL

2

,

L

OCAL

3

,

L

OCAL

4

,

L

OCAL

5

,

L

OCAL

6

,

L

OCAL

7

.

S

YSLOG

F

ACILITY

is the facility level for all messages forwarded from the unit to the syslog server. This allows all messages
received from the IAD to be filtered by facility level. See RFC3164: The BSD Syslog Protocol.

The remaining Syslog parameters have the following level choices:

FATAL (Highest priority)

ALERT

CRITICAL

ERROR

WARNING

NOTICE

INFO

DEBUG (Lowest priority)

Every log message generated by the IAD has a reporting level priority. If the message priority is lower than
the configured priority for the destination log, the message is not forwarded to the syslog daemon. See
RFC3164: The BSD Syslog Protocol. The lower the log level, the more messages that will be generated.
Setting reporting levels to DEBUG may negatively affect the performance of the IAD, including causing
the IAD to reset.

ADTRAN Utilities may malfunction if messages are received in the Unix format.

This does not have to correspond to the facility level shown in the terminal mode option.
See SYSLOG using Terminal Mode on page 59
.

ADTRAN recommends using DEBUG for only short periods of time, and for debug
purposes only.