Section 4 User Interface Guide

Total Access 600 Series System Manual

84

© 2004 ADTRAN, Inc.

61200624L1-1B

I

NTERFACES

(FXS) > C

ONFIG

> S

VC

M

ODE

Indicates whether the module is

I

N

S

ERVICE

or

O

UT

OF

S

VC

. This does not indicate whether the port has

been mapped. For proper operation, the port must be mapped using the

DS0 M

APS

menu. Default is

I

N

S

ERVICE

.

I

NTERFACES

(FXS) > C

ONFIG

> L

INE

Z

Sets the line impedance. Choices are

600

OHMS

, 900

OHMS

, 600

OHMS

+ 2.16

µ

F, 900

OHMS

+ 2.16

µ

F,

and

A

UTO

. The line impedance of each port is based on the size of the network. Default is

600

OHMS

.

I

NTERFACES

(FXS) > C

ONFIG

> M

SG

I

ND

This is better referred to as On-Hook Message Waiting. When this is set to

E

NABLE

,

talk path is always

open, even in On-Hook conditions, in order for these FSK message tones to pass through. Default is

D

ISABLE

. Enabling on-hook message waiting will allow message lamp usage but will cause a lower

on-hook voltage. Disabling this feature will allow higher on-hook voltage but will not allow on-hook
messaging other than caller ID.

I

NTERFACES

(FXS) > C

ONFIG

> B

ATT

M

ODE

Configures the on-hook battery voltage. For most IAD installs, the FXS loop is short with 6 to 7 V present
on tip / ring. To reduce power dissipated during off-hook conditions, the battery is lowered for short loop
lengths. When set to

A

UTO

S

WITCH

, the IAD uses a higher on-hook battery voltage (48-52 V). When

off-hook, it automatically switches to low battery (24-26 V) to minimize power dissipation. When set to

L

OW

B

ATTERY

mode, the higher battery is not used and the voltage is a constant 26 V even while on-hook.

The tip/ring voltage is reduced to 26 V when using the

L

OW

B

ATTERY

mode.

I

NTERFACES

(FXS) > C

ONFIG

> F

WD

D

ISC

T

IMER

Specifies the interval of battery removal during a forward disconnect state. Choices are

F

OLLOW

S

WITCH

(default),

500

MS

,

750

MS

,

1000

MS

, and

2000

MS

. When using ATM mode, there is an additional choice of

I

GNORE

S

WITCH

. If the timer is set to

F

OLLOW

S

WITCH

, the Total Access 6XX will follow the switch at all

times; this is normal operation. If a time period has been selected, the Total Access 6XX will remove
battery for the specified time period OR as long as the switch requests battery removal, whichever is
longer. For example, if the timer expires but the switch continues to request battery removal, the Total
Access 6XX will follow the switch and continue to remove battery. For ATM mode, if the timer is set to

I

GNORE

S

WITCH

, the IAD will never remove battery.

I

NTERFACES

(FXS) > C

ONFIG

> T

ANDEM

Sets the port to use E&M signaling on the T-Span and either loop start or ground start supervision on the
analog 2-wire interface. To access submenus for this item, use the arrow keys to scroll to the

T

ANDEM

column for the corresponding module, and then press

<E

NTER

>

.

I

NTERFACES

(FXS) > C

ONFIG

> T

ANDEM

> C

ONVERSION

M

ODE

Sets the port to either

L

OOP

S

TART

or

G

ROUND

S

TART

mode. Default is

L

OOP

S

TART

.

I

NTERFACES

(FXS) > C

ONFIG

> T

ANDEM

> S

UPERVISION

Sets the supervision method used to either

I

MMEDIATE

or

W

INK

. Default is

I

MMEDIATE

.