Total Access 600 Series System Manual

Section 4 User Interface Guide

61200624L1-1B

© 2004 ADTRAN, Inc.

53

S

YSTEM

C

ONFIG

> M

ANAGEMENT

> T

ELNET

A

CCESS

> A

CCESS

Sets

A

CCESS

to

O

N

or

O

FF

to allow or block telnet access to the unit. The factory default value for this

parameter is

O

N

.

S

YSTEM

C

ONFIG

> M

ANAGEMENT

> T

ELNET

A

CCESS

> A

UTHEN

M

ETHOD

Set up the Telnet authentication method from this menu. The choices are

L

OCAL

P

ASSWORD

,

R

ADIUS

,

L

OCAL

/R

ADIUS

, and

R

ADIUS

/L

OCAL

.

L

OCAL

/R

ADIUS

indicates that the unit will try Local Password

Authentication first, and if that fails, it will try Radius Authentication.

R

ADIUS

/L

OCAL

indicates that the unit

will try Radius authentication first, and if that fails, it will try Local Password authentication. The default is

L

OCAL

P

ASSWORD

.

S

YSTEM

C

ONFIG

> M

ANAGEMENT

> T

ELNET

P

ORT

Defines the TCP port number used when establishing a Telnet session. Normal Telnet port is 23. Enter a
customized port number if desired. Make certain the Telnet program you use is configured for the same
port number (if using a customized port number).

S

YSTEM

C

ONFIG

> M

ANAGEMENT

> T

ELNET

A

CCESS

> U

SER

L

IST

Add Telnet users and control the Telnet access conditions through this menu.

#

Display the index number of the Telnet users. Up to four users can be configured for access to the
unit. Each user can be assigned a security level and idle time.

N

AME

The name is a text string of the user name for this session. The factory default is

U

NASSIGNED

in the

N

AME

field.You must enter a username in this field (up to 15 characters) because the Telnet entry is

not activated until it is assigned a valid username. Editing the

U

NASSIGNED

default to be blank is

allowed for a single Telnet entry; duplicate usernames are not allowed. During an active Telnet
session the

N

AME

is displayed in the Telnet Information field located at the bottom of the menu

screen.

P

ASSWORD

When the authenticating method is

L

OCAL

P

ASSWORD

, or

L

OCAL

/R

ADIUS

, this text string is used for

the password. You can enter up to 30 characters in this field. The factory default is no entry in this
field.

I

DLE

T

IME

(

MINS

)

This sets the amount of time in minutes you can be idle before you are automatically logged off. The
factory default is

10

MINUTES

. The range is

1

TO

255

MINUTES

.

L

EVEL

This is the security level granted to the user. Table 3 on page 54 gives a brief description of each
level. The factory default is

F

ULL

.