Total Access 600 Series System Manual

Section 4 User Interface Guide

61200624L1-1B

© 2004 ADTRAN, Inc.

171

FXS Interface Setup Instructions

Step

Action

1

From the main menu, select I

NTERFACES

.

2

Highlight the C

ONFIG

menu for the FXS interface and press <E

NTER

>.

3

Right arrow to select M

ODE

and choose L

OOP

S

TART

, G

ROUND

S

TART

,

T

ANDEM

(E&M), TR08 S

INGLE

, TR08 UVG, or DPO.

This mode should be set based on the network configuration and the
operation of each FXS port. All FXS ports are independent and do not
need to have the same mode.

4

Set the T

X

(dB) or transmit direction level for each port. The default

value is recommended.

5

Set the R

X

(dB) or received direction level for each port. The default

value is recommended.

6

Set the S

VC

M

ODE

to I

N

S

ERVICE

to activate the port.

7

Set the L

INE

Z (line impedance) of each port based on the size of the

network. The default value is recommended.

8

Set the M

SG

I

ND

to D

ISABLE

or E

NABLE

. When set to E

NABLE

, talk path is

always open, even in on-hook conditions, in order for FXS message
tones to pass through. Disabling this feature will allow higher on-hook
voltage but will not allow on-hook messaging other than caller ID.

9

Configure the on-hook battery voltage using the B

ATT

M

ODE

field. For

most IAD installs, the FXS loop is short with 6 to 7 V present on tip / ring.
To reduce power dissipated during off-hook conditions, the battery is
lowered for short loop lengths. When set to A

UTO

S

WITCH

, the IAD uses

a higher on-hook battery voltage (48-52 V). When off-hook, it
automatically switches to low battery (24-26 V) to minimize power
dissipation. When set to L

OW

B

ATTERY

mode, the higher battery is not

used and the voltage is a constant 26 V even while on-hook. The tip/ring
voltage is reduced to 26 V when using the L

OW

B

ATTERY

mode.

10

Specify the interval of battery removal during a forward disconnect state

using the F

WD

D

ISC

T

IMER

field. Choices are F

OLLOW

S

WITCH

(default),

500

MS

, 750

MS

, 1000

MS

, and 2000

MS

. When using ATM mode, there is

an additional choice of I

GNORE

S

WITCH

. If the timer is set to F

OLLOW

S

WITCH

, the

Total Access 6XX will follow the switch at all times; this is normal
operation. If a time period has been selected, the Total Access 6XX will
remove battery for the specified time period OR as long as the switch
requests battery removal, whichever is longer. For example, if the timer
expires but the switch continues to request battery removal, the Total
Access 6XX will follow the switch and continue to remove battery. For
ATM mode, if the timer is set to I

GNORE

S

WITCH

, the IAD will never

remove battery.