ADTRAN 600R User Manual

Page 76

Advertising
background image

Section 4 User Interface Guide

Total Access 600 Series System Manual

74

© 2004 ADTRAN, Inc.

61200624L1-1B

I

NTERFACES

(T1) > S

TATUS

> A

LARMS

> C

URRENT

A

LARMS

Displays the current alarms on the T1 interface. An asterisk in a field indicates that an alarm is active.

I

NTERFACES

(T1) > S

TATUS

> A

LARMS

> A

LARM

H

ISTORY

Displays the alarm history for the T1 interface. An asterisk in a field indicates that an alarm has occurred
on the T1 interface since the last clear history. Refer to Interfaces (T1) > Status > Alarms > Current
Alarms
for more details on listed
alarm conditions.

I

NTERFACES

(T1) > S

TATUS

> A

LARMS

> C

LEAR

H

ISTORY

Selecting this activator will clear the Alarm History for the T1 interface.

I

NTERFACES

(T1) > S

TATUS

> R

X

L

EVEL

Displays the level (in dB) of the received T1 signal on the interface.

I

NTERFACES

(T1) > T

EST

These options are used to initiate local and remote loopback tests and display the test status.

I

NTERFACES

(T1) > T

EST

> L

OC

LB

Loopback of the local unit. Choices are

N

ONE

,

L

INE

,

and

P

AYLOAD

.

L

INE

loopback loops all of the received

data back toward the network. The transmitted data is the identical line code that was received, including
any bipolar violations.

L

INE

loopbacks tests right up to the T1 interface of the ADTRAN unit.

P

AYLOAD

loopback is similar to line loopback except that the framing is extracted from the received data and then
regenerated for the transmitted data.

P

AYLOAD

loopbacks not only verify the T1 circuit, but also the internal

hardware of the local ADTRAN device.

N

ONE

disables the loopback test. Default is

N

ONE

.

I

NTERFACES

(T1) > T

EST

> R

EM

LB

Sends a loopback command across the network to a remote unit over the FDL, which causes the remote
unit initiate a local

L

INE

or

P

AYLOAD

loopback (whichever is specified). The remote loopback is only

available when the T1 is configured for ESF mode.

I

NTERFACES

(T1) > T

EST

> T

EST

S

TATUS

Indicates whether a test is in progress.

LOS

Loss of Signal. No signal detected on port interface.

RED

Not able to frame data received on the port. Alternately referred to as Out of
Frame (OOF). RED alarm most frequently occurs when there is a framing
mismatch on the T1 interface.

YELLOW

Remote alarm indicator (RAI) being received on port. A YELLOW alarm indicates
that the remote unit is not receiving properly framed information from your unit.

BLUE

Receiving unframed all ones from the port alarm indicator signal (AIS). A BLUE
alarm is sent to notify the unit that equipment upstream is disconnected or
malfunctioning.