Appendix D. Configuring the Unit for DSX-1 Applications

The Total Access 600 Series systems are available with an integrated DSX-1 interface for both voice and
data applications. Regardless of the application (either voice or data), the Total Access 6XX has the ability
to map DS0s from the network T1 to DS0s on the DSX-1 interface (cross-connect) without affecting the
data present on the DS0s. This feature allows the Total Access 6XX to support voice with dedicated
signaling channels (ISDN), voice with in-channel signaling information (Robbed Bit Signaling (RBS) to a
PBX, key system, etc.), as well as clear channel data to an external T1 router.

Initial Setup

It is best to configure Total Access 6XX TDM applications by following the order of the top-level menus.
For example, first configure the system parameters using the

S

YSTEM

I

NFO

and

S

YSTEM

C

ONFIG

menus.

Next, configure the Layer 1 parameters using the

I

NTERFACES

menu. Once the Layer 1 information is

configured, proceed to the Layer 2 setup using the

L2 P

ROTOCOL

menus. Follow the Layer 2 setup with the

data “routing” menus (either

B

RIDGE

or

R

OUTER

). Establish packet forwarding and blocking using the

S

ECURITY

menus. Lastly, configure the physical mappings using the

DS0 M

APS

menus.

The following example provides details for configuring the Total Access 6XX to pass analog voice over
the DSX-1 interface (using RBS), digital voice (fractional PRI with D-Channel), and data bandwidth. The
Total Access 6XX provides a single DSX-1 interface, so it is unlikely that your application will require all
three features on the DSX-1 interface simultaneously; therefore ignore any steps that do not pertain to your
application.

Perform the following steps in order to configure the applications (

I

NTERFACES

through

DS0 M

APS

).

S

YSTEM

I

NFO

and

S

YSTEM

C

ONFIG

parameters should be set according to your system need. Refer to System

Info on page 49 and System Config on page 51 for more details.

1. Setting up the Interfaces

For more details on the configuration parameters discussed in this section, refer to the following pages:

Network T1 menus beginning on

page 71

DSX-1 menus beginning on

page 78

T1 Interface Setup Instructions

Step

Action

1

From the main menu, select I

NTERFACES

.

2

Highlight the C

ONFIG

menu for the T1 interface and press <E

NTER

>.

3

Right arrow to select F

ORMAT

and choose ESF or SF.

This format must match the format used by the other units in the network.

4

Set the L

INE

C

ODE

to B8ZS or AMI.