Configuring an ipv6 syslog server – Brocade TurboIron 24X Series Configuration Guide User Manual

Page 182

Advertising
background image

148

Brocade TurboIron 24X Series Configuration Guide

53-1003053-01

IPv6 management (IPv6 host support)

The source <ipv6-address> parameter specifies an IPv6 address to be used as the origin of
the ping packets.

NOTE

The outgoing-interface and source options are available only on router code and not on switch
code.

The count <number> parameter specifies how many ping packets the router sends. You can
specify from 1 - 4294967296. The default is 1.

The timeout <milliseconds> parameter specifies how many milliseconds the router waits for a
reply from the pinged device. You can specify a timeout from 1 - 4294967294 milliseconds.
The default is 5000 (5 seconds).

The ttl <number> parameter specifies the maximum number of hops. You can specify a TTL
from 1 - 255. The default is 64.

The size <bytes> parameter specifies the size of the ICMP data portion of the packet. This is
the payload and does not include the header. You can specify from 0 - 10173. The default is
16.

The quiet keyword hides informational messages such as a summary of the ping parameters
sent to the device, and instead only displays messages indicating the success or failure of the
ping. This option is disabled by default.

The verify keyword verifies that the data in the echo packet (the reply packet) is the same as
the data in the echo request (the ping). By default the device does not verify the data.

The data <1 - 4 byte hex> parameter lets you specify a specific data pattern for the payload
instead of the default data pattern, "abcd", in the packet's data payload. The pattern repeats
itself throughout the ICMP message (payload) portion of the packet.

NOTE

For parameters that require a numeric value, the CLI does not check that the value you enter is
within the allowed range. Instead, if you do exceed the range for a numeric value, the software
rounds the value to the nearest valid value.

The brief keyword causes ping test characters to be displayed. The following ping test
characters are supported.
! Indicates that a reply was received.

. Indicates that the network server timed out while waiting for a reply.

U Indicates that a destination unreachable error PDU was received.

I Indicates that the user interrupted ping.

Configuring an IPv6 Syslog server

To enable IPv6 logging, specify an IPv6 Syslog server. Enter a command such as the following.

TurboIron(config)#log host ipv6 2000:DB8:e0bb::4/128

Syntax: log host ipv6 <ipv6-address> [ <udp-port-num> ]

The<ipv6-address> must be in hexadecimal using 16-bit values between colons as
documented in RFC 2373.

The <udp-port-num> optional parameter specifies the UDP application port used for the
Syslog facility.