Image file types

TurboIron#verify md5 secondary 01c410d6d153189a4a5d36c955653861

TurboIron#.........................Done

Size = 2044830, MD5 01c410d6d153189a4a5d36c955653862

Verification FAILED.

In the previous example, the codes did not match, and verification failed. If verification succeeds,
the output will look like this.

TurboIron#verify md5 secondary 01c410d6d153189a4a5d36c955653861

TurboIron#.........................Done

Size = 2044830, MD5 01c410d6d153189a4a5d36c955653861

Verification SUCEEDED.

The following examples show this process for SHA-1 and CRC32 algorithms.

TurboIron#verify sha secondary 49d12d26552072337f7f5fcaef4cf4b742a9f525

TurboIron#.........................Done

Size = 2044830, sha 49d12d26552072337f7f5fcaef4cf4b742a9f525

Verification SUCCEEDED.

and

TurboIron#verify crc32 secondary b31fcbc0

TurboIron#.........................Done

Size = 2044830, CRC32 b31fcbc0

Verification SUCCEEDED.

Image file types

This section lists the boot and flash image file types supported on the TurboIron X Series of
switches and how to install them. For information about a specific version of code, refer to the
release notes.

Upgrading software

Use the following procedures to upgrade the software.

Upgrading the boot code

Follow the steps given below to upgrade the boot code.

1. Place the new boot code on a TFTP server to which the device has access.

2. Enter the following command at the Privileged EXEC level of the CLI to copy the boot code from

the TFTP server into flash memory:

copy tftp flash <ip-addr> <image-file-name> bootrom

TABLE 16

Software image files

Product

Boot image

1

1.

Flash image

TurboIron X Series

TRZxxxxx.bin

TISxxxxx.bin (Layer 2)