VRRP-E

To stop link down occurrences from being reported, enter the following.

TurboIron(config)#no snmp-server enable traps link-down

Syntax: [no] snmp-server enable traps <trap-type>

Disabling Syslog messages and traps for CLI access

TurboIron X Seriesdevices send Syslog messages and SNMP traps when a user logs into or out of
the User EXEC or Privileged EXEC level of the CLI. The feature applies to users whose access is
authenticated by an authentication-method list based on a local user account, RADIUS server, or
TACACS/TACACS+ server.

NOTE

The Privileged EXEC level is sometimes called the “Enable” level, because the command for
accessing this level is enable.

The feature is enabled by default.

Examples of Syslog messages for CLI access
When a user whose access is authenticated by a local user account, a RADIUS server, or a
TACACS/TACACS+ server logs into or out of the CLI User EXEC or Privileged EXEC mode, the
software generates a Syslog message and trap containing the following information:

The time stamp

The user name

Whether the user logged in or out

The CLI level the user logged into or out of (User EXEC or Privileged EXEC level)

NOTE

Messages for accessing the User EXEC level apply only to access through Telnet. The device does
not authenticate initial access through serial connections but does authenticate serial access to the
Privileged EXEC level. Messages for accessing the Privileged EXEC level apply to access through the
serial connection or Telnet.

The following examples show login and logout messages for the User EXEC and Privileged EXEC
levels of the CLI.

Syntax: show logging

TurboIron#show logging

Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)

Buffer logging: level ACDMEINW, 12 messages logged

level code: A=alert C=critical D=debugging M=emergency E=error

I=informational N=notification W=warning

Static Log Buffer:

Dec 15 19:04:14:A:Fan 1, fan on right connector, failed

Dynamic Log Buffer (50 entries):

Oct 15 18:01:11:info:dg logout from USER EXEC mode

Oct 15 17:59:22:info:dg logout from PRIVILEGE EXEC mode

Oct 15 17:38:07:info:dg login to PRIVILEGE EXEC mode