Brocade TurboIron 24X Series Configuration Guide

197

53-1003053-01

Configuring LLDP

Per device

You can change the maximum number of neighbors for which LLDP data will be retained for the
entire system.

For example, to change the maximum number of LLDP neighbors for the entire device to 26, enter
the following command.

TurboIron(config)#lldp max-total-neighbors 26

Syntax: [no] lldp max-total-neighbors <value>

Use the [no] form of the command to remove the static configuration and revert to the default
value of 392.

where <value> is a number between 16 and 65536. The default number of LLDP neighbors per
device is 392.

Use the show lldp command to view the configuration.

Per port

You can change the maximum number of LLDP neighbors for which LLDP data will be retained for
each port. By default, the maximum number is four and you can change this to a value between
one and 64.

For example, to change the maximum number of LLDP neighbors to six, enter the following
command.

TurboIron(config)#lldp max-neighbors-per-port 6

Syntax: [no] lldp max-neighbors-per-port <value>

Use the [no] form of the command to remove the static configuration and revert to the default
value of four.

where <value> is a number from 1 to 64. The default is number of LLDP neighbors per port is four.

Use the show lldp command to view the configuration.

Enabling LLDP SNMP notifications and syslog messages

SNMP notifications and Syslog messages for LLDP provide management applications with
information related to MIB data updates and general status.

When you enable LLDP SNMP notifications, corresponding Syslog messages are enabled as well.
When you enable LLDP SNMP notifications, the device will send traps and corresponding Syslog
messages whenever there are changes to the LLDP data received from neighboring devices.

LLDP SNMP notifications and corresponding Syslog messages are disabled by default. To enable
them, enter a command such as the following at the Global CONFIG level of the CLI.

TurboIron(config)#lldp enable snmp notifications ports e 2 to 6

The above command enables SNMP notifications and corresponding Syslog messages on ports 2
and 6. By default, the device will send no more than one SNMP notification and Syslog message
within a five second period. If desired, you can change this interval. Refer to

“Specifying the

minimum time between SNMP traps and syslog messages”

on page 198.

Syntax: [no] lldp enable snmp notifications ports ethernet <port-list> | all