Table 22.

Y-cable clock-end cross-connects for high or critical reliability

From Stratum 3 Clock

To Y-cable clock end
(primary)

To Y-cable clock end
(secondary)

Lead
Name

Lead
Color/
Terminal

Lead
Name

Lead Color/
Terminal

Lead
Name

Lead Color/
Terminal

RREF1

W-BL/1

V-O/43

TREF1

BL-W/2

O-V/44

RREF2

W-O/3

V-O/43

TREF2

O-W/4

O-V/44

Continued on next page

Table 23.

Circuit-pack cross-connects for high or critical reliability

From Stratum 3 Clock

To TN780 carrier A

To TN780 carrier B

Lead
Name

Lead Color/
Terminal

Lead
Name

Lead Color/
Terminal

Lead
Name

Lead Color/
Terminal

BCLKRTN

R-O/13

ALRM5B

V-G/45

ALRM5B

V-G/45

BCLKLST

O-R/14

ALRM5A

G-V/47

ALRM5A

G-V/47

BPWRRTN

R-BR/17

ALRM4B

BK-BL/21

ALRM4B

BK-BL/21

BPWRLST

BR-R/18

ALRM4A

BL-BK/22

ALRM4A

BL-BK /22

REF2RTN

W-BR/7

ALRM3B

R-BR/17

ALRM3B

R-BR/17

REF2LST

BR-W/8

ALRM3A

BR-R/18

ALRM3A

BR-R/18

SCLKRTN

R-BL/11

ALRM2B

R-BL/11

ALRM2B

R-BL/11

SCLKLST

BL-R/12

ALRM2A

BL-R/12

ALRM2A

BL-R/12

SPWRRTN

R-G/15

ALRM1B

Y-BL/31

ALRM1B

Y-BL/31

SPWRLST

G-R/17

ALRM1A

BL-Y/32

ALRM1A

BL-Y/32

REF1RTN

W-G/5

ALRM0B

W-BR/7

ALRM0B

W-BR/7

REF1LST

G-W/7

ALRM0A

BR-W/8

ALRM0A

BR-W/8

CCA01R

R-S/19

EXTSYN0T

V-BL/41

CCA01T

S-R/20

EXTSYN0R

BL-V/42

Continued on next page